The recorded add.y channel spans -1.267 to 0 source units in this reference run. It starts at 0 and ends at -1.14. The first recorded maximum occurs at 0 seconds and the first minimum at 79,096,499,405 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Measured_SmallScale. The source file places it under Fluid, Geothermal, Borefields, Heat Transfer. We used the 101 stored values for add.y over the interval 0 to 85,049,999,360 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name groTemRes (Ground Temperature Response), meaDat (Combi Time Table), TBorHol (Add), scaFac (Gain). The source declares sizFac = 375.0. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel TBorHol.y covers 296.119 to 339.3 source units. At 79,096,499,405 s, the primary value is -1.267 and the companion is 339.283. Their signed difference is -340.55 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Measured small scale. The simulated add.y channel runs from -1.267 to 0 source units over 85,049,999,360 seconds.
Measured small scale. The simulated add.y channel runs from -1.267 to 0 source units over 85,049,999,360 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 850,499,994 seconds. Subtracting 0 from -0.7471 gives -0.7471 source units. Its location brackets the change within one saved interval of 850,499,994 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

add.y (source units)

TBorHol.y (source units)

0

0

296.1194

8.505e+08

-0.747055

321.9501

1.701e+10

-0.831029

336.8127

3.402e+10

-0.9472097

338.2842

5.103e+10

-0.9988018

338.8089

6.804e+10

-1.039681

338.9194

7.90965e+10

-1.266682

339.2835

8.505e+10

-1.140369

339.2961

What to check on site

The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.