Assume a controller scans one row at a time and spends 1.5 ms on each row, including its settling and read period. Multiply the number of rows by that slot time to find the interval between visits to the same row. With matrix rows at 5, the worked result is 7.5 on the row revisit time at 1.5 ms per row (ms) scale.

The recorded quantity and the calculated result

Keep three columns in a commissioning export: the original matrix rows, the configuration used in the conversion and the resulting row revisit time at 1.5 ms per row (ms). Recompute the result for the lower, middle and upper worked points before interpreting a field difference. A change in range, units or representation can otherwise be mistaken for a change in the process.

Two points to check independently

Take the neighbouring worked points 4 and 5 on the input axis. The results are 6 and 7.5, giving a signed difference of 1.5. The table preserves the calculated values before display rounding. These are calculated examples under the stated assumptions. They are not readings from a ProSense installation.

Matrix keypad scan latency. Matrix rows changes from 2 to 10 and the calculated Row revisit time at 1.5 ms per row (ms) changes from 3 to 15.
Matrix keypad scan latency. Matrix rows changes from 2 to 10 and the calculated Row revisit time at 1.5 ms per row (ms) changes from 3 to 15. Figure by Industry Applied.

Worked data

Matrix rows

Row revisit time at 1.5 ms per row (ms)

2

3

3

4.5

4

6

5

7.5

6

9

8

12

10

15

Checking the ends of the working range

The final interval in this example runs from 5 to 10 on the matrix rows axis. Its average change in row revisit time at 1.5 ms per row (ms) per input unit is 1.5. This is a two-point slope for that interval. To check a spreadsheet or a gateway calculation, enter 10 in a separate test row and compare its result against 15 at the displayed precision.

Installation and interpretation

Contact debounce may require detections on successive scans, adding time beyond the revisit interval. Simultaneous keys can create a separate ambiguity in some matrices. Specify the debounce policy and allowed key combinations at the operator interface.

For a repeatable verification, capture a small known case and a second case well away from it. Check whether the difference follows the response in the table, then restore the working configuration and repeat one reading. Store a separate status field for missing or invalid input. Substituting zero would make a dropped observation indistinguishable from a legitimate numerical zero.

Implementation and worked data

The source implementation is maintained in the .NET IoT device project. The component notes and manufacturer references document the supported device and its interfaces. Download the worked numerical example.