The TBorFieOut[1].T trace covers 13.5 to 19.678 °C, a temperature span of 6.178 K. The first recorded maximum occurs at 15,001,632 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named MassFlowRatePulse50. The source file places it under Fluid, Geothermal, Zoned Borefields, FEFLOW. We used the 101 stored values for TBorFieOut[1].T over the interval 0 to 15,465,600 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 5 recorded variables. Alongside the primary output there are TBorFieIn[1].T, TBorFieOut[1].T, TOut.y[1], TBorFieOut[2].T, TOut.y[2]. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel TBorFieOut[2].T covers 286.65 to 292.516 K. At 15,465,600 s, the primary value is 292.591 and the companion is 292.036. Their signed difference is 0.5552 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Mass flow rate pulse50. The simulated TBorFieOut[1].T channel runs from 286.65 to 292.828 K over 15,465,600 seconds.
Mass flow rate pulse50. The simulated TBorFieOut[1].T channel runs from 286.65 to 292.828 K over 15,465,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 154,656 seconds. Subtracting 286.65 from 291.982 gives 5.332 K. Its location brackets the change within one saved interval of 154,656 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

TBorFieOut[1].T (K)

TBorFieOut[2].T (K)

0

286.65

286.65

154656

291.982

291.9827

3093120

291.8808

291.7062

6186240

292.5901

292.3776

9279360

292.3745

291.8977

1.237248e+07

292.7831

292.4826

1.500163e+07

292.8282

292.516

1.54656e+07

292.591

292.0358

What to check on site

The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.