The recorded massFlowRateMultiplier.port_b.m_flow channel spans -50 to 0 kg/s in this reference run. It starts at 0 and ends at -50. The first recorded maximum occurs at 0 seconds and the first minimum at 10 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named MassFlowRateMultiplier. The source file places it under Fluid. We used the 101 stored values for massFlowRateMultiplier.port_b.m_flow over the interval 0 to 10 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name massFlowRateMultiplier (Mass Flow Rate Multiplier), ram_m_flow (Ramp), sou (Mass Flow Source T), sin (Boundary p T). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel massFlowRateMultiplier1.port_b.m_flow covers -50 to 0 kg/s. At 5 s, the primary value is -25 and the companion is -12.75. Their signed difference is -12.25 kg/s, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Mass flow rate multiplier. The simulated massFlowRateMultiplier.port_b.m_flow channel runs from -50 to 0 kg/s over 10 seconds.
Mass flow rate multiplier. The simulated massFlowRateMultiplier.port_b.m_flow channel runs from -50 to 0 kg/s over 10 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 10 seconds gives a net -250 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

massFlowRateMultiplier.port_b.m_flow (kg/s)

massFlowRateMultiplier1.port_b.m_flow (kg/s)

0

0

0

2

-10

-2.16

4

-20

-8.24

6

-30

-18.24

8

-40

-32.16

8.1

-40.5

-32.9589

8.2

-41

-33.7676

10

-50

-50

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.