The recorded hex.dp1 channel spans 10 to 110 source units in this reference run. It starts at 110 and ends at 10. The first recorded maximum occurs at 0 seconds and the first minimum at 302.4 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ConstantEffectiveness. The source file places it under Fluid, Mass Exchangers. We used the 101 stored values for hex.dp1 over the interval 0 to 360 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name TWat (Ramp), TDb (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel hex.dp2 covers 5 to 205 source units. At 302.4 s, the primary value is 10 and the companion is 205. Their signed difference is -195 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Mass exchangers constant effectiveness. The simulated hex.dp1 channel runs from 10 to 110 source units over 360 seconds.
Mass exchangers constant effectiveness. The simulated hex.dp1 channel runs from 10 to 110 source units over 360 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 277.2 to 280.8 seconds. Subtracting 48 from 42 gives -6 source units. Its location brackets the change within one saved interval of 3.6 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

hex.dp1 (source units)

hex.dp2 (source units)

0

110

5

72

110

205

144

110

205

216

110

205

277.2

48.00002

205

280.8

41.99998

205

288

30

205

302.4

10

205

360

10

205

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.