The lowest observed group mean is -89.72 for tape group 47. The highest is 3.081 for group 45, a difference of 92.801 on the source response scale. Across all 158 numeric records the response median is 2.87.

What was measured

The OAKLEY data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as amplitude. It preserves the source scale and its sign. The file contains 11 numeric fields per accepted row.

Spread across the original readings

The two endpoint groups have 33 and 14 observations. Their medians are -99 and 3.111, respectively. The figure groups the original entries by the recorded tape value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

Magnetic tape reference amplitude. The lowest and highest group means are -89.72 and 3.081 on the source response scale.
Magnetic tape reference amplitude. The lowest and highest group means are -89.72 and 3.081 on the source response scale. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 97 after the header. Its response is 2.868. The overall arithmetic mean is -39.625, so this observation is 42.493 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 101.978, calculated by subtracting -99 from 2.978.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

tape group

Observations

Mean response

Median response

Minimum response

Maximum response

45

14

3.081071

3.1115

2.963

3.159

47

33

-89.7197

-99

-99

3.166

49

55

-52.62707

-99

-99

3.122

58

56

-8.012643

2.907

-99

3.114

Implications for an industrial comparison

Record fixture connections, instrument range, excitation level and temperature alongside the measured result. Repeatability within one setup can remain good even when fixtures differ between laboratories. A useful acceptance run includes both a repeat measurement without disturbing the setup and a repeat after a normal reconnection.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.

Cover photograph by Peter Xie, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.