The lowest observed group mean is 630.495 for lab group 5. The highest is 666.178 for group 7, a difference of 35.682 on the source response scale. Across all 480 numeric records the response median is 646.628.

What was measured

The JAHANMI2 data file has 50 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as ceramic strength. It preserves the source scale and its sign. The file contains 16 numeric fields per accepted row.

Spread across the original readings

The two endpoint groups have 60 and 60 observations. Their medians are 621.763 and 680.204, respectively. The figure groups the original entries by the recorded lab value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

Machined ceramic strength across laboratories. The lowest and highest group means are 630.495 and 666.178 on the source response scale.
Machined ceramic strength across laboratories. The lowest and highest group means are 630.495 and 666.178 on the source response scale. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 378 after the header. Its response is 647.323. The overall arithmetic mean is 650.077, so this observation is -2.754 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 112.29, calculated by subtracting 596.052 from 708.341.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

lab group

Observations

Mean response

Median response

Minimum response

Maximum response

1

60

645.6125

628.7095

512.394

769.391

2

60

655.2121

646.101

504.167

815.754

3

60

633.3161

634.051

382.133

790.382

4

60

650.3897

648.8635

436.237

778.333

5

60

630.4955

621.7625

345.294

776.197

6

60

656.2608

655.777

545.303

776.488

7

60

666.1775

680.204

472.463

821.654

8

60

663.1543

676.2665

530.68

795.833

Implications for an industrial comparison

Compare the specimen geometry, preparation, loading direction, conditioning and endpoint before using this distribution in a materials decision. Failure observations from a controlled test do not directly provide a field failure probability. A comparison with current production also needs the number of specimens withdrawn before the stated endpoint.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.