The recorded extHeaRad.port_a.Q_flow channel spans -460.26 to 460.26 W in this reference run. It starts at -460.26 and ends at 460.26. The first recorded maximum occurs at 1,000,000 seconds and the first minimum at 0 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named LongwaveHeatTransfer. The source file places it under Buildings, Components, Radiative Heat Transfer. We used the 101 stored values for extHeaRad.port_a.Q_flow over the interval 0 to 1,000,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name extHeaRad (Exterior Heat Radiation), intHeaRadLin (Heat Radiation), zonLwDist (Zone Lw Distribution), ramp (Ramp). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel intHeaRadLin.port_b.Q_flow covers -472.317 to 472.317 W. At 0 s, the primary value is -460.26 and the companion is -472.317. Their signed difference is 12.056 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Longwave heat transfer. The simulated extHeaRad.port_a.Q_flow channel runs from -460.26 to 460.26 W over 1,000,000 seconds.
Longwave heat transfer. The simulated extHeaRad.port_a.Q_flow channel runs from -460.26 to 460.26 W over 1,000,000 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed extHeaRad.port_a.Q_flow samples by the trapezoidal rule gives 0 kWh over 1,000,000 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

extHeaRad.port_a.Q_flow (W)

intHeaRadLin.port_b.Q_flow (W)

0

-460.2604

-472.3165

10000

-451.0552

-462.8702

200000

-276.1562

-283.3899

400000

-92.05208

-94.4633

600000

92.05208

94.4633

800000

276.1562

283.3899

1000000

460.2604

472.3165

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.