The lowest observed group mean is 0.3293 for load group 150,000 to 750,000. The highest is 1.954 for group 2,400,000 to 3,000,000, a difference of 1.625 on the source response scale. Across all 40 numeric records the response median is 1.146.
What was measured
The PONTIUS data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as deflection. It preserves the source scale and its sign. The file contains 2 numeric fields per accepted row.
Spread across the original readings
The two endpoint groups have 10 and 10 observations. Their medians are 0.3294 and 1.954, respectively. The figure groups the original entries by the recorded load value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

One row you can check
To check a real observation, take numeric row 11 after the header. Its response is 1.2. The overall arithmetic mean is 1.143, so this observation is 0.05655 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 1.029, calculated by subtracting 0.6297 from 1.659.
The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.
Worked data
load group | Observations | Mean response | Median response | Minimum response | Maximum response |
|---|---|---|---|---|---|
150,000 to 750,000 | 10 | 0.329319 | 0.32944 | 0.11019 | 0.54803 |
900,000 to 1,500,000 | 10 | 0.87444 | 0.874805 | 0.65694 | 1.0915 |
1,650,000 to 2,250,000 | 10 | 1.416017 | 1.41606 | 1.20001 | 1.63194 |
2,400,000 to 3,000,000 | 10 | 1.954069 | 1.954185 | 1.73947 | 2.16844 |
Implications for an industrial comparison
A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.
Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.
Source file and worked data
The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.
Cover photograph by RDNE Stock project, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.