The lowest observed group mean is 2.284 for grouping of silicon group 1 to 8. The highest is 3.037 for group 24 to 30, a difference of 0.7535 on the source response scale. Across all 450 numeric records the response median is 2.453.

What was measured

The LITHOGRA data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as line width in a silicon wafer. It preserves the source scale and its sign. The file contains 6 numeric fields per accepted row.

Spread across the original readings

The two endpoint groups have 120 and 105 observations. Their medians are 2.223 and 3.012, respectively. The figure groups the original entries by the recorded grouping of silicon value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

Lithographic wafer linewidth. The lowest and highest group means are 2.284 and 3.037 on the source response scale.
Lithographic wafer linewidth. The lowest and highest group means are 2.284 and 3.037 on the source response scale. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 194 after the header. Its response is 2.448. The overall arithmetic mean is 2.532, so this observation is -0.08424 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 0.9193, calculated by subtracting 2.05 from 2.97.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

grouping of silicon group

Observations

Mean response

Median response

Minimum response

Maximum response

1 to 8

120

2.283508

2.222963

0.971193

3.857221

9 to 15

105

2.299577

2.310817

0.746546

3.76427

16 to 23

120

2.543023

2.504764

1.169269

4.293889

24 to 30

105

3.037035

3.011574

1.938037

5.168668

Implications for an industrial comparison

Record fixture connections, instrument range, excitation level and temperature alongside the measured result. Repeatability within one setup can remain good even when fixtures differ between laboratories. A useful acceptance run includes both a repeat measurement without disturbing the setup and a repeat after a normal reconnection.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.

Cover photograph by Peter Xie, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.