The recorded casTem.TCas channel spans 318.909 to 321.361 source units in this reference run. It starts at 321.361 and ends at 318.909. The first recorded maximum occurs at 0 seconds and the first minimum at 1 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named CaseTemperature. The source file places it under Fluid, Data Centers, Racks, Liquid. We used the 101 stored values for casTem.TCas over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name casTem (Case Temperature), V_flow (Ramp), TIn (Constant), P (Constant). The source declares nPar = 4. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The primary channel spends 54.5% of its saved checkpoints at or above 320.135 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 320.207 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0.98 to 0.99 seconds. Subtracting 318.964 from 318.937 gives -0.02747 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | casTem.TCas (source units) |
|---|---|
0 | 321.3614 |
0.2 | 320.9584 |
0.4 | 320.4889 |
0.6 | 319.9824 |
0.8 | 319.4532 |
0.98 | 318.9641 |
0.99 | 318.9366 |
1 | 318.9092 |
What to check on site
Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.