The recorded winLin.propsBus_a.surfRad.Q_flow channel spans -0.4218 to 17.894 W in this reference run. It starts at 0 and ends at 2.663. The first recorded maximum occurs at 130,000 seconds and the first minimum at 610,000 seconds.
The system being tested
The KU Leuven IDEAS project publishes the IDEAS test named WindowLinearisation. The source file places it under Buildings, Components. We used the 101 stored values for winLin.propsBus_a.surfRad.Q_flow over the interval 0 to 1,000,000 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name outerWall (Outer Wall), winNonLin (Window), winLin (Window). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel winNonLin.propsBus_a.surfRad.Q_flow covers -0.4205 to 17.962 W. At 10,000 s, the primary value is 15.719 and the companion is 15.915. Their signed difference is -0.1959 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
Integrating the signed winLin.propsBus_a.surfRad.Q_flow samples by the trapezoidal rule gives 2.479 kWh over 1,000,000 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | winLin.propsBus_a.surfRad.Q_flow (W) | winNonLin.propsBus_a.surfRad.Q_flow (W) |
|---|---|---|
0 | 0 | 0 |
10000 | 15.71876 | 15.91467 |
130000 | 17.89368 | 17.96245 |
200000 | 12.63036 | 12.7112 |
400000 | 5.42441 | 5.422785 |
600000 | 0.4237855 | 0.4223807 |
610000 | -0.4217712 | -0.4204882 |
800000 | 12.02247 | 12.08865 |
1000000 | 2.662562 | 2.654893 |
What to check on site
Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.