The recorded CaseLin.heatingSystem.QHeaSys channel spans 0 to 1,199 source units in this reference run. It starts at 0 and ends at 869.367. The first recorded maximum occurs at 890,000 seconds and the first minimum at 0 seconds.
The system being tested
The KU Leuven IDEAS project publishes the IDEAS test named ConvectionVerification. The source file places it under Buildings, Tests. We used the 101 stored values for CaseLin.heatingSystem.QHeaSys over the interval 0 to 1,000,000 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 4 recorded variables. Alongside the primary output there are CaseNonLin.heatingSystem.QHeaSys, CaseLin.heatingSystem.QHeaSys, CaseLin.building.TSensor[1], CaseNonLin.building.TSensor[1]. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The two named channels have separate paths in the model. CaseLin.heatingSystem.QHeaSys begins at −0 and ends at 869.37. CaseNonLin.heatingSystem.QHeaSys begins at −0 and ends at 871.28. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 120,000 to 130,000 seconds. Subtracting 951.274 from 0 gives -951.274 source units. Its location brackets the change within one saved interval of 10,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | CaseLin.heatingSystem.QHeaSys (source units) | CaseNonLin.heatingSystem.QHeaSys (source units) |
|---|---|---|
0 | 0 | 0 |
120000 | 951.2739 | 949.5604 |
130000 | 0 | 0 |
200000 | 857.3052 | 889.7263 |
400000 | 726.4205 | 717.8763 |
600000 | 914.1472 | 919.9121 |
800000 | 941.5216 | 990.381 |
890000 | 1198.943 | 1249.302 |
1000000 | 869.3675 | 871.2782 |
What to check on site
Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.