The lowest observed group mean is 12.75 for lime content group 1. The highest is 35.5 for group 2, a difference of 22.75 on the source response scale. Across all 8 numeric records the response median is 16.5.

What was measured

The CLAYTILE data file has 50 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as percent defective in a batch. It preserves the source scale and its sign. The file contains 8 numeric fields per accepted row.

Spread across the original readings

The two endpoint groups have 4 and 4 observations. Their medians are 14 and 34, respectively. The figure groups the original entries by the recorded lime content value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

Lime content and clay-tile defects. The lowest and highest group means are 12.75 and 35.5 on the source response scale.
Lime content and clay-tile defects. The lowest and highest group means are 12.75 and 35.5 on the source response scale. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 2 after the header. Its response is 17. The overall arithmetic mean is 24.125, so this observation is -7.125 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 19.5, calculated by subtracting 10.5 from 30.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

lime content group

Observations

Mean response

Median response

Minimum response

Maximum response

1

4

12.75

14

6

17

2

4

35.5

34

6

68

Implications for an industrial comparison

A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.