The recorded Opening_Orifice.dp channel spans -35.425 to 0.03681 Pa in this reference run. It starts at -35.425 and ends at 0.03681. The first recorded maximum occurs at 3 seconds and the first minimum at 0 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named LargeHorizontalOpening. The source file places it under Airflow, Multizone. We used the 101 stored values for Opening_Orifice.dp over the interval 0 to 300 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name MFsensor_Orifice (Mass Flow Rate), Ori_Mixingvol_MF2 (Mass Flow Rate), vol1 (Mixing Volume), vol (Mixing Volume). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel MF_Orifice.y starts at -52,020, ends at 1,679 and has a recorded range of -52,020 to 1,679 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Large horizontal opening. The simulated Opening_Orifice.dp channel runs from -35.425 to 0.03681 Pa over 300 seconds.
Large horizontal opening. The simulated Opening_Orifice.dp channel runs from -35.425 to 0.03681 Pa over 300 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 3 seconds. Subtracting -35.425 from 0.03681 gives 35.462 Pa. Its location brackets the change within one saved interval of 3 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

Opening_Orifice.dp (Pa)

MF_Orifice.y (source units)

0

-35.42479

-52019.75

3

0.03681085

1678.62

60

0.03681085

1678.62

120

0.03681085

1678.62

180

0.03681085

1678.62

240

0.03681085

1678.62

300

0.03681085

1678.62

What to check on site

Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.