The TPip1.T trace covers 25 to 45 °C, a temperature span of 20 K. The first recorded maximum occurs at 612 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named InternalResistancesTwoUTube. The source file places it under Fluid, Geothermal, Borefields, Boreholes. We used the 101 stored values for TPip1.T over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name TWal (Fixed Temperature), TPip2 (Fixed Temperature), TPip1 (Prescribed Temperature), T_ramp (Ramp). The source declares Rgb_val = 0.572601, Rgg1_val = 0.0406121, Rgg2_val = 0.216904, RCondGro_val = 0.195099. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel intRes2UTub.capFil1.T covers 298.15 to 304.207 K. At 612 s, the primary value is 318.15 and the companion is 299.113. Their signed difference is 19.037 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 36 seconds. Subtracting 298.15 from 299.35 gives 1.2 K. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | TPip1.T (K) | intRes2UTub.capFil1.T (K) |
|---|---|---|
0 | 298.15 | 298.15 |
36 | 299.35 | 298.1553 |
612 | 318.15 | 299.1131 |
720 | 318.15 | 299.3906 |
1440 | 318.15 | 300.9446 |
2160 | 318.15 | 302.1944 |
2880 | 318.15 | 303.267 |
3600 | 318.15 | 304.2072 |
What to check on site
The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.
