The internal multilayer wall temperatures starts at 20 °C and finishes at 24.722 °C in this reference run. The model stores absolute temperature in kelvin. Its observed minimum and maximum convert to 20 °C and 24.722 °C.
What the reference test measures
The Buildings model named ConductorMultiLayer comes from Lawrence Berkeley National Laboratory. The saved result covers simulation time 0 to 86,400 seconds. Industry Applied extracted 101 checkpoints for con.T[2] and kept the original signed values. The regular output spacing is 864 seconds. The solver may take different internal steps.
The model definition identifies conv (Interior). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.
Reading the two channels
At 62,208 seconds, con.T[2] is 297.814 and con.T[4] is 293.235. Subtracting the second channel from the first gives +4.579 K, the largest absolute separation on their common saved grid. The channels have distinct roles in the model, so this difference describes the two traces and is not a calibrated instrument error.
![Internal multilayer wall temperatures. In the simulated ConductorMultiLayer case, con.T[2] ranges from 293.15 to 297.872 K over 86,400 seconds.](https://static.wixstatic.com/media/21e41b_b212e308d65c43988e8bc361263b7d1f~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_b212e308d65c43988e8bc361263b7d1f~mv2.png)
Reproducing the largest recorded change
Between the stored points at 44,064 and 44,928 seconds, con.T[2] changes from 293.832 to 294.863. Subtracting the earlier reading gives +1.03 K. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.
The extrema in the table and figure are extrema of the stored series. A solver’s internal peak, a field logger’s alarm value and a maximum derived from this export can differ. Preserve the sampling settings when comparing results.
Worked data
Simulation time (s) | con.T[2] (K) | con.T[4] (K) |
|---|---|---|
0 | 293.15 | 293.15 |
21600 | 293.15 | 293.15 |
43200 | 293.15 | 293.15 |
44064 | 293.8322 | 293.15 |
44928 | 294.8626 | 293.1504 |
64800 | 297.8248 | 293.2468 |
86400 | 297.8724 | 293.3039 |
Applying the result to an operating site
Material boundaries alter resistance and heat capacity. A surface temperature does not locate the main internal gradient by itself. Record layer order, thickness and the coordinate of each comparison point when relating the model to a physical assembly.
For a local engineering comparison, write the measurement boundary, operating duty and instruments into the test record. Select comparable load or weather periods, then compare the measured trace with the simulated quantities. Establish a local acceptance tolerance using the intended duty and measurement uncertainty.