The realExpression.y trace ranges from 0.083348 to 8 across 101 saved checkpoints. It begins at 8 and finishes at 0.083348 after 100,000 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named InternalHEXOneUTube. The source file places it under Fluid, Geothermal, Borefields, Boreholes. We used the 101 stored values for realExpression.y over the interval 0 to 100,000 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 2 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The primary channel spends 1.0% of its saved checkpoints at or above 4.042 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 0.123 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 1,000 seconds. Subtracting 8 from 0.08792 gives -7.912 source units. Its location brackets the change within one saved interval of 1,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | realExpression.y (source units) |
|---|---|
0 | 8 |
1000 | 0.08792038 |
8000 | 0.08334789 |
20000 | 0.08334789 |
40000 | 0.08334789 |
60000 | 0.08334789 |
80000 | 0.08334789 |
100000 | 0.08334789 |
What to check on site
The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.