The TBorFieOut[1].T trace covers 8.092 to 18.934 °C, a temperature span of 10.842 K. The first recorded maximum occurs at 309,312 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named InletTemperaturePulse. The source file places it under Fluid, Geothermal, Zoned Borefields, FEFLOW. We used the 101 stored values for TBorFieOut[1].T over the interval 0 to 15,465,600 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 5 recorded variables. Alongside the primary output there are TBorFieIn[1].T, TBorFieOut[1].T, TOut.y[1], TBorFieOut[2].T, TOut.y[2]. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel TBorFieIn[1].T covers 280.15 to 293.15 K. At 0 s, the primary value is 286.65 and the companion is 293.15. Their signed difference is -6.5 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Inlet temperature pulse. The simulated TBorFieOut[1].T channel runs from 281.242 to 292.084 K over 15,465,600 seconds.
Inlet temperature pulse. The simulated TBorFieOut[1].T channel runs from 281.242 to 292.084 K over 15,465,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 12,527,136 to 12,681,792 seconds. Subtracting 292.07 from 281.476 gives -10.595 K. Its location brackets the change within one saved interval of 154,656 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

TBorFieOut[1].T (K)

TBorFieIn[1].T (K)

0

286.65

293.15

309312

292.0836

293.15

3093120

281.7513

280.15

6186240

291.808

293.15

9279360

281.3981

280.15

1.036195e+07

281.2419

280.15

1.237248e+07

291.9811

293.15

1.252714e+07

292.0703

293.15

1.268179e+07

281.4757

280.15

1.54656e+07

281.2793

280.15

What to check on site

The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.