The recorded pumpBus.rpmMea channel spans 0 to 3,106 source units in this reference run. It starts at 1,200 and ends at 0. The first recorded maximum occurs at 402 seconds and the first minimum at 504 seconds.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named PumpSpeedControlled. The source file places it under Fluid, Movers, Pumps Polynomial Based. We used the 101 stored values for pumpBus.rpmMea over the interval 0 to 600 seconds. This is a simulated test with specified inputs and boundaries.

The source declares m_flow_nominal = 1. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel pumpBus.rpmSet covers 1,100 to 4,350 source units. At 504 s, the primary value is 0 and the companion is 4,350. Their signed difference is -4,350 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Ing the pump speed controlled. The simulated pumpBus.rpmMea channel runs from 0 to 3,106 source units over 600 seconds.
Ing the pump speed controlled. The simulated pumpBus.rpmMea channel runs from 0 to 3,106 source units over 600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 498 to 504 seconds. Subtracting 3,106 from 0 gives -3,106 source units. Its location brackets the change within one saved interval of 6 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

pumpBus.rpmMea (source units)

pumpBus.rpmSet (source units)

0

1200

1100

120

1750

1750

240

3091.232

4350

360

3103.389

4350

402

3106.46

4350

480

3106.459

4350

498

3106.459

4350

504

0

4350

600

0

4350

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.