The archived response ranges from 89 to 104. The median is 97 and the central half of the measurements extends from 94 to 99. Those figures use all 7 numeric observations in this source series and retain its original measurement scale.

What was measured

The BOXWELD data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as breaking strenght. It preserves the source scale and its sign. The file contains 2 numeric fields per accepted row.

Spread across the original readings

The tenth percentile is 90.2 and the ninetieth is 101.6. They provide a narrower description of the typical spread than the minimum and maximum. The largest and smallest observed records are separated by 15. This is the range of this sample, rather than a guaranteed operating envelope.

Inertial weld breaking strength. The 25th, 50th and 75th percentiles of the measurements are 94, 97 and 99.
Inertial weld breaking strength. The 25th, 50th and 75th percentiles of the measurements are 94, 97 and 99. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 7 after the header. Its response is 97. The overall arithmetic mean is 96.571, so this observation is 0.4286 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 5, calculated by subtracting 94 from 99.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

Percentile

Observed response (source scale)

Number of numeric rows

0

89

7

10

90.2

7

25

94

7

50

97

7

75

99

7

90

101.6

7

100

104

7

Implications for an industrial comparison

Compare the specimen geometry, preparation, loading direction, conditioning and endpoint before using this distribution in a materials decision. Failure observations from a controlled test do not directly provide a field failure probability. A comparison with current production also needs the number of specimens withdrawn before the stated endpoint.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data