The TRetOut.T trace covers 20 to 25.588 °C, a temperature span of 5.588 K. The first recorded maximum occurs at 460 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named IehSummer. The source file places it under Airflow, air handler. We used the 101 stored values for TRetOut.T over the interval 0 to 500 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name bui (Boundary p T), TRetOut (Temperature Two Port), XRet (X p Tphi), TRet (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel TSupOut.T covers 293.15 to 294.308 K. At 70 s, the primary value is 298.633 and the companion is 294.008. Their signed difference is 4.626 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Indirect evaporative heat exchanger using summer data set. The simulated TRetOut.T channel runs from 293.15 to 298.738 K over 500 seconds.
Indirect evaporative heat exchanger using summer data set. The simulated TRetOut.T channel runs from 293.15 to 298.738 K over 500 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 5 seconds. Subtracting 293.15 from 294.49 gives 1.34 K. Its location brackets the change within one saved interval of 5 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

TRetOut.T (K)

TSupOut.T (K)

0

293.15

293.15

5

294.4904

293.2519

100

298.7148

294.1423

200

298.7364

294.2858

300

298.7375

294.3051

400

298.7377

294.3075

460

298.7378

294.3078

500

298.7378

294.3078

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.