The recorded con1.y channel spans 0 to 0.4022 source units in this reference run. It starts at 0 and ends at 0.4022. The first recorded maximum occurs at 276 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Humidifier_u. The source file places it under Fluid, Humidifiers. We used the 101 stored values for con1.y over the interval 0 to 1,200 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name sou (Mass Flow Source T), humSte (Humidifier u), senTem1 (Temperature Two Port), con1 (Lim PID). The source declares m_flow_nominal = 3000/1000/20. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel con2.y covers 0 to 0.7179 source units. At 132 s, the primary value is 0.3937 and the companion is 0.7179. Their signed difference is -0.3241 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Ideal humidifier. The simulated con1.y channel runs from 0 to 0.4022 source units over 1,200 seconds.
Ideal humidifier. The simulated con1.y channel runs from 0 to 0.4022 source units over 1,200 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 120 to 132 seconds. Subtracting 0 from 0.3937 gives 0.3937 source units. Its location brackets the change within one saved interval of 12 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

con1.y (source units)

con2.y (source units)

0

0

0

120

0

0

132

0.3937474

0.7178712

240

0.4022175

0.4056026

276

0.4022178

0.403699

480

0.4022178

0.4022188

720

0.4022178

0.4022179

960

0.4022178

0.4022178

1200

0.4022178

0.4022178

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.