The recorded flo.eas.heaPorAir.Q_flow channel spans 0 to 4,711 W in this reference run. It starts at 4,711 and ends at 893.357. The first recorded maximum occurs at 7,344,000 seconds and the first minimum at 7,348,320 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named IdealHeatingCoolingSpring. The source file places it under Thermal Zones, Energy Plus 24 2 0, Small Office. We used the 101 stored values for flo.eas.heaPorAir.Q_flow over the interval 7,344,000 to 7,776,000 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 22 recorded variables. Alongside the primary output there are flo.TAirCor, flo.TAirSou, flo.TAirNor, flo.TAirEas, flo.TAirWes. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The companion channel flo.nor.heaPorAir.Q_flow covers 0 to 7,942 W. At 7,344,000 s, the primary value is 4,711 and the companion is 7,942. Their signed difference is -3,230 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
Integrating the signed flo.eas.heaPorAir.Q_flow samples by the trapezoidal rule gives 32.735 kWh over 432,000 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | flo.eas.heaPorAir.Q_flow (W) | flo.nor.heaPorAir.Q_flow (W) |
|---|---|---|
7344000 | 4711 | 7941.5 |
7348320 | 0 | 0 |
7430400 | 0 | 0 |
7516800 | 0 | 0 |
7603200 | 315.3422 | 1495.813 |
7689600 | 1421.871 | 991.2419 |
7776000 | 893.3575 | 1346.021 |
What to check on site
Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.