The recorded con1.y channel spans 0 to 0.5073 source units in this reference run. It starts at 0 and ends at 0.5073. The first recorded maximum occurs at 264 seconds and the first minimum at 0 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named HeaterCooler_u. The source file places it under Fluid, Heat Exchangers. We used the 101 stored values for con1.y over the interval 0 to 1,200 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name sin (Boundary p T), heaSte (Heater Cooler u), senTem1 (Temperature Two Port), con1 (Lim PID). The source declares m_flow_nominal = 3000/1000/20. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel con2.y covers 0 to 1 source units. At 132 s, the primary value is 0.5003 and the companion is 1. Their signed difference is -0.4997 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 120 to 132 seconds. Subtracting 0 from 0.5003 gives 0.5003 source units. Its location brackets the change within one saved interval of 12 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | con1.y (source units) | con2.y (source units) |
|---|---|---|
0 | 0 | 0 |
120 | 0 | 0 |
132 | 0.500305 | 1 |
240 | 0.5072698 | 0.5098009 |
264 | 0.50727 | 0.5066772 |
480 | 0.50727 | 0.5072699 |
720 | 0.50727 | 0.50727 |
960 | 0.50727 | 0.50727 |
1200 | 0.50727 | 0.50727 |
What to check on site
Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.
Cover photograph by Jakub Zerdzicki, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.