The temRet.T trace covers 15.565 to 39.708 °C, a temperature span of 24.143 K. The first recorded maximum occurs at 544,320 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named TwoRoomsWithStorage. The source file places it under Hydronic Heating. We used the 101 stored values for temRet.T over the interval 0 to 604,800 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name pumBoi (Speed Controlled y), pumRad (Speed Controlled y), roo1 (Mixed Air), roo2 (Mixed Air). The source declares nRoo = 2, VRoo = 4*6*3, Q_flow_nominal = 2200, scaFacRad = 1.5. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel tan.vol[1].T covers 293.15 to 343.811 K. At 520,128 s, the primary value is 289.004 and the companion is 343.156. Their signed difference is -54.152 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 538,272 to 544,320 seconds. Subtracting 290.572 from 312.858 gives 22.285 K. Its location brackets the change within one saved interval of 6,048 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | temRet.T (K) | tan.vol[1].T (K) |
|---|---|---|
0 | 293.15 | 293.15 |
120960 | 297.9924 | 337.1389 |
241920 | 297.7282 | 337.3327 |
362880 | 288.7146 | 331.5989 |
483840 | 297.1547 | 338.4977 |
538272 | 290.5724 | 340.8 |
544320 | 312.8576 | 335.3564 |
604800 | 298.7203 | 343.2874 |
What to check on site
Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.


