The recorded hydraulicBus.TFwrdInMea channel spans 303.055 to 323.15 source units in this reference run. It starts at 303.15 and ends at 323.15. The first recorded maximum occurs at 376 seconds and the first minimum at 176 seconds.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named Injection. The source file places it under Systems, Hydraulic Modules. We used the 101 stored values for hydraulicBus.TFwrdInMea over the interval 0 to 800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name hydRes (Pressure Drop). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel hydraulicBus.TFwrdOutMea covers 303.15 to 323.151 source units. At 296 s, the primary value is 323.13 and the companion is 303.489. Their signed difference is 19.641 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Hydraulic modules injection circuit. The simulated hydraulicBus.TFwrdInMea channel runs from 303.055 to 323.15 source units over 800 seconds.
Hydraulic modules injection circuit. The simulated hydraulicBus.TFwrdInMea channel runs from 303.055 to 323.15 source units over 800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 192 to 200 seconds. Subtracting 306.8 from 311.908 gives 5.108 source units. Its location brackets the change within one saved interval of 8 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

hydraulicBus.TFwrdInMea (source units)

hydraulicBus.TFwrdOutMea (source units)

0

303.15

303.15

160

303.0645

303.3246

176

303.0551

303.3459

192

306.8

303.367

200

311.9077

303.3773

320

323.1461

303.5246

376

323.1503

303.8583

480

323.15

308.4836

640

323.15

320.9322

800

323.15

323.1511

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.