Subtract a fitted 0.25 m offset before raising the difference to the power 1.6 and multiplying by 3.2. These coefficients are illustrative. At 0.7 on the gauge stage (m) scale, the worked result is 0.8918 on the illustrative rated discharge (m³/s) scale. The figure and table let you check the result against a second operating point.

Set up the field measurement

Low stages are especially sensitive to a small shift in the reference level. Compare against direct gaugings near the low-flow end. Keep the reference observation alongside the calculation, with the instrument identification, observation period and units. This makes it possible for the next shift to distinguish a new operating condition from a change in how the observation was recorded.

Two operating points

Compare the two adjacent inputs of 0.5 and 0.7 m. The calculation gives 0.3482 at the first and 0.8918 at the second. The signed change is 0.5436 on the output scale. A spreadsheet cross-check should reproduce both rows and the direction of change before it is copied through the remaining conditions.

Illustrative rated discharge (m³/s) plotted against gauge stage (m). Across the example the output changes from 0 to 3.46.
Illustrative rated discharge (m³/s) plotted against gauge stage (m). Across the example the output changes from 0 to 3.46. Figure by Industry Applied.

Worked data

Gauge stage (m)

Illustrative rated discharge (m³/s)

0.25

0

0.35

0.08038037

0.5

0.3482202

0.7

0.8918463

1

2.019519

1.3

3.459815

Checking the working range

At the two ends of the example, an input of 0.25 gives 0 and an input of 1.3 gives 3.46. Use a value near each end to check your implementation. Testing only the middle row can conceal an incorrect offset, an inverted ratio or a unit conversion applied twice.

Interpreting the result

This synthetic curve has no approved gauging location. Backwater, channel change and extrapolation can invalidate a site rating. If measured performance sits outside the worked range, first repeat the comparison using field inputs and the same boundary. Preserve the original reading in the export. A discrepancy is easier to investigate when the field observation and the calculated output occupy separate columns.

Source and calculation data

For the underlying measurement context, see the USGS explanation of stage and discharge. The operating values and sensitivity analysis here are an Industry Applied worked example. Download the input and output values to verify the calculation with the values from your own site.