Divide a 4.096 V full input span by the number of codes, then divide one code width by the square root of twelve. In the worked example, Converter resolution of 14 bits gives ideal rms quantisation noise of 72.169 µV.

Set up the field measurement

Compare the ideal result with a measured quiet-input standard deviation. Use the same bandwidth, reference and sample processing when comparing two acquisitions. Keep the reference observation alongside the calculation, with the instrument identification, observation period and units. This makes it possible for the next shift to distinguish a new operating condition from a change in how the observation was recorded.

Two operating points

At 12 bits the calculated ideal rms quantisation noise is 288.675 µV. At 14 bits it is 72.169 µV. Subtracting the first output from the second gives -216.506 µV. These values give two independent checkpoints for a spreadsheet or a logger conversion.

Ideal RMS quantisation noise (µV) plotted against converter resolution (bits). Across the example the output changes from 4,619 to 4.511.
Ideal RMS quantisation noise (µV) plotted against converter resolution (bits). Across the example the output changes from 4,619 to 4.511. Figure by Industry Applied.

Worked data

Converter resolution (bits)

Ideal RMS quantisation noise (µV)

8

4618.802

10

1154.701

12

288.6751

14

72.16878

16

18.0422

18

4.510549

Checking the working range

At the two ends of the example, an input of 8 gives 4,619 and an input of 18 gives 4.511. Use a value near each end to check your implementation. Testing only the middle row can conceal an incorrect offset, an inverted ratio or a unit conversion applied twice.

Interpreting the result

The uniform quantisation-error assumption needs an appropriate signal. Reference noise, analogue front-end noise and interference can dominate real performance. If measured performance sits outside the worked range, first repeat the comparison using field inputs and the same boundary. Preserve the original reading in the export. A discrepancy is easier to investigate when the field observation and the calculated output occupy separate columns.

Source and calculation data

For the underlying measurement context, see Analog Devices’ tutorial on quantisation noise. The operating values and sensitivity analysis here are an Industry Applied worked example. Download the input and output values to verify the calculation with the values from your own site.