Convert collected millilitres to litres, divide by a 0.01 square metre opening, then scale a 20-minute test to one hour. In the worked example, Collected volume in 20 minutes of 50 mL gives application rate of 15 mm/h.

Set up the field measurement

Measure the collector opening. A tapered container with marks down its side can have a different effective collecting area from its base. Keep the reference observation alongside the calculation, with the instrument identification, observation period and units. This makes it possible for the next shift to distinguish a new operating condition from a change in how the observation was recorded.

Two operating points

At 35 mL the calculated application rate is 10.5 mm/h. At 50 mL it is 15 mm/h. Subtracting the first output from the second gives 4.5 mm/h. These values give two independent checkpoints for a spreadsheet or a logger conversion.

Application rate (mm/h) plotted against collected volume in 20 minutes (ml). Across the example the output changes from 3 to 30.
Application rate (mm/h) plotted against collected volume in 20 minutes (ml). Across the example the output changes from 3 to 30. Figure by Industry Applied.

Worked data

Collected volume in 20 minutes (mL)

Application rate (mm/h)

10

3

20

6

35

10.5

50

15

70

21

100

30

Checking the working range

At the two ends of the example, an input of 10 gives 3 and an input of 100 gives 30. Use a value near each end to check your implementation. Testing only the middle row can conceal an incorrect offset, an inverted ratio or a unit conversion applied twice.

Interpreting the result

Use several cans at measured positions. A high reading at one sprinkler is poor evidence for the area-wide mean. If measured performance sits outside the worked range, first repeat the comparison using field inputs and the same boundary. Preserve the original reading in the export. A discrepancy is easier to investigate when the field observation and the calculated output occupy separate columns.

Source and calculation data

For the underlying measurement context, see FAO’s technical handbook on pressurised irrigation. The operating values and sensitivity analysis here are an Industry Applied worked example. Download the input and output values to verify the calculation with the values from your own site.