The sim.Qgai.Q_flow series gives a net -254.268 kWh over 5,000,000 s when the saved power samples are joined by straight lines. The highest recorded power is 1,536.3 W. The sign follows the model’s measurement boundary. It matters when a connector can exchange energy in either direction.
The system being tested
The KU Leuven IDEAS project publishes the IDEAS test named EnergyConservationValidation. The source file places it under Buildings, Tests. We used the 101 stored values for sim.Qgai.Q_flow over the interval 0 to 5,000,000 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 1 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The primary channel spends 99.0% of its saved checkpoints at or above -10,036 W, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is -183.073 W. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Reproduce the calculation
Integrating the signed sim.Qgai.Q_flow samples by the trapezoidal rule gives -254.268 kWh over 5,000,000 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | sim.Qgai.Q_flow (W) |
|---|---|
0 | -21608.21 |
50000 | -579.2881 |
1000000 | 29.87253 |
2000000 | -206.9149 |
3000000 | -131.9255 |
4000000 | -384.5186 |
4100000 | 1536.299 |
5000000 | -401.6043 |
What to check on site
Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.