The archived response ranges from 30 to 68. The median is 44.5 and the central half of the measurements extends from 37.25 to 54. Those figures use all 8 numeric observations in this source series and retain its original measurement scale.
What was measured
The AMRF data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as hole to hole distance. It preserves the source scale and its sign. The file contains 8 numeric fields per accepted row.
Spread across the original readings
The tenth percentile is 31.4 and the ninetieth is 64.5. They provide a narrower description of the typical spread than the minimum and maximum. The largest and smallest observed records are separated by 38. This is the range of this sample, rather than a guaranteed operating envelope.

One row you can check
To check a real observation, take numeric row 1 after the header. Its response is 49. The overall arithmetic mean is 46.5, so this observation is 2.5 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 16.75, calculated by subtracting 37.25 from 54.
The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.
Worked data
Percentile | Observed response (source scale) | Number of numeric rows |
|---|---|---|
0 | 30 | 8 |
10 | 31.4 | 8 |
25 | 37.25 | 8 |
50 | 44.5 | 8 |
75 | 54 | 8 |
90 | 64.5 | 8 |
100 | 68 | 8 |
Implications for an industrial comparison
A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.
Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.
Source file and worked data
The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.