The recorded hea.TOut temperature spans -0.13935 °C to 29.849 °C in this simulation. That is a change of 29.988 K. The first saved maximum occurs at 252 s. The source trace and download retain absolute temperatures in kelvin.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named Nicol2001HeatingEU. The source file places it under Occupants, Residential, Heating. We used the 101 stored values for hea.TOut over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name occ (Boolean Step), TOut (Sine), hea (Nicol2001 Heating EU). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
At 2,016 s, hea.TOut reads 289.505 K and hea.on reads 0. Across the run, the second channel ranges from 0 to 1. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 1,980 to 2,016 seconds. Subtracting 286.12 from 289.505 gives 3.385 K. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | hea.TOut (K) | hea.on (logical state) |
|---|---|---|
0 | 288 | 0 |
252 | 302.9988 | 0 |
720 | 273.2657 | 0 |
756 | 273.0107 | 0 |
1440 | 293.5219 | 0 |
1980 | 286.12 | 0 |
2016 | 289.5054 | 0 |
2160 | 300.6649 | 0 |
2880 | 277.7318 | 1 |
3600 | 279.1832 | 0 |
What to check on site
Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Units in the source model
The component declarations identify the scale of the exported variables. In this run, hea.on uses logical state. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.