The recorded TVol.T temperature spans 15.999 °C to 20.831 °C in this simulation. That is a change of 4.8314 K. The first saved maximum occurs at 46,656 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named AirHeater_T. The source file places it under Fluid, Heat Exchangers. We used the 101 stored values for TVol.T over the interval 0 to 172,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name hea (Heater T). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 25,920 s, TVol.T is 292.734 K and THeaOut.T is 298.206 K. Subtracting the second value from the first gives -5.4718 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Heater with prescribed outlet temperature and air as the medium. The simulated TVol.T channel runs from 289.149 to 293.981 K over 172,800 seconds.
Heater with prescribed outlet temperature and air as the medium. The simulated TVol.T channel runs from 289.149 to 293.981 K over 172,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 24,192 to 25,920 seconds. Subtracting 289.381 from 292.734 gives 3.353 K. Its location brackets the change within one saved interval of 1,728 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

TVol.T (K)

THeaOut.T (K)

0

289.15

289.15

24192

289.3807

289.3806

25920

292.7338

298.2056

34560

293.1515

293.1515

46656

293.9808

293.9808

69120

292.329

292.3301

74304

289.1494

290.0217

103680

289.1508

289.5741

138240

293.6953

293.6954

172800

289.15

290.519

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.