The TVol.T trace covers 15.989 to 20.825 °C, a temperature span of 4.836 K. The first recorded maximum occurs at 133,056 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named AirHeater_u. The source file places it under Fluid, Heat Exchangers. We used the 101 stored values for TVol.T over the interval 0 to 172,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name hea (Heater Cooler u). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel THeaOut.T covers 289.15 to 297.907 K. At 25,920 s, the primary value is 292.557 and the companion is 297.907. Their signed difference is -5.35 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Heater with prescribed heat input and air as the medium. The simulated TVol.T channel runs from 289.139 to 293.975 K over 172,800 seconds.
Heater with prescribed heat input and air as the medium. The simulated TVol.T channel runs from 289.139 to 293.975 K over 172,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 110,592 to 112,320 seconds. Subtracting 289.377 from 292.557 gives 3.18 K. Its location brackets the change within one saved interval of 1,728 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

TVol.T (K)

THeaOut.T (K)

0

289.15

289.15

34560

293.1523

293.1521

69120

292.3747

292.4078

74304

289.1388

290.011

103680

289.1521

289.5758

110592

289.3769

289.372

112320

292.5571

297.9071

133056

293.9752

293.975

138240

293.6984

293.7019

172800

289.15

290.5191

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.