The signed flow trace gives a net -7.449e-13 kg over 1 s, using the trapezoidal rule between saved samples. The smallest and largest reported rates are -0.01 kg/s and 0.01 kg/s. Check the positive flow direction in the model before using the sign to describe delivery or return.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named MixingVolumePrescribedHeatFlowRate. The source file places it under Fluid, Mixing Volumes. We used the 101 stored values for vol.ports[1].m_flow over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name heaFlo (Heat Flow Sensor), sou (Mass Flow Source T), bou (Fixed Boundary), preHeaFlo (Prescribed Heat Flow). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 0.98 s, vol.ports[1].m_flow reads -0.0096 kg/s and vol.heatPort.T reads 303.15 K. Across the run, the second channel ranges from 303.15 K to 313.15 K. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Heat transfer to volume. The simulated vol.ports[1].m_flow channel runs from -0.01 to 0.01 kg/s over 1 seconds.
Heat transfer to volume. The simulated vol.ports[1].m_flow channel runs from -0.01 to 0.01 kg/s over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 1 seconds gives a net 0 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

vol.ports[1].m_flow (kg/s)

vol.heatPort.T (K)

0

0.01

313.15

0.2

0.006

313.15

0.4

0.002

313.15

0.6

-0.002

303.15

0.8

-0.006

303.15

0.97

-0.009399999

303.15

0.98

-0.0096

303.15

1

-0.01

303.15

What to check on site

Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.