The published senHeaFlo.Q_flow signal spans 0 to 418,872.656 W in the reference run. It starts at 0 and finishes at 418,872.656. The signed change between those endpoint samples is +418,872.656 W.

What the reference test measures

The Buildings model named HeatMeter comes from Lawrence Berkeley National Laboratory. The saved result covers simulation time 0 to 60 seconds. Industry Applied extracted 101 checkpoints for senHeaFlo.Q_flow and kept the original signed values. The regular output spacing is 0.6 seconds. The solver may take different internal steps.

The model definition identifies heaFloRat (Fixed Heat Flow), sou (Mass Flow Source T), sin (Boundary p T). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.

Settings to preserve when repeating the experiment

The published test declares vol.V = 0.1, m_flow_nominal = 10. Those numbers use the units and component definitions in the linked model. Start with the declared configuration when reproducing the reference result, then vary one setting at a time. Changing the input waveform and the component response in the same comparison makes it difficult to identify the source of a difference.

Reading the two channels

The companion channel heaFloRat.Q_flow spans 420,000 to 420,000 W across its 2 stored values. The primary trace first reaches its recorded maximum at 60 seconds and its minimum at 0 seconds. A time-aligned comparison preserves the meaning and units of each channel.

Heat-meter power signal. In the simulated HeatMeter case, senHeaFlo.Q_flow ranges from 0 to 418,872.656 W over 60 seconds.
Heat-meter power signal. In the simulated HeatMeter case, senHeaFlo.Q_flow ranges from 0 to 418,872.656 W over 60 seconds. Figure by Industry Applied.

Reproducing the largest recorded change

Between the stored points at 2.4 and 3 seconds, senHeaFlo.Q_flow changes from 57,358.86 to 76,900.32. Subtracting the earlier reading gives +19,541.46 W. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.

The extrema in the table and figure are extrema of the stored series. A solver’s internal peak, a field logger’s alarm value and a maximum derived from this export can differ. Preserve the sampling settings when comparing results.

Worked data

Simulation time (s)

senHeaFlo.Q_flow (W)

heaFloRat.Q_flow (W)

0

0

420000

2.4

57358.86

420000

3

76900.32

420000

15

316513.4

420000

30

397060.6

420000

45

414915.1

420000

60

418872.7

420000

Applying the result to an operating site

Heat transfer rate combines flow and an energy difference across a declared boundary. Compare the inlet and outlet pairing and recognise the sign convention. Cumulative heat requires time integration of this power signal, with gaps handled explicitly.

For a local engineering comparison, write the measurement boundary, operating duty and instruments into the test record. Select comparable load or weather periods, then compare the measured trace with the simulated quantities. Establish a local acceptance tolerance using the intended duty and measurement uncertainty.