The rayleighNumber.Gr trace ranges from -1.767e+09 to 2.122e+09 across 101 saved checkpoints. It begins at 0 and finishes at 0 after 50 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named RayleighNumber. The source file places it under Fluid, Heat Exchangers. We used the 101 stored values for rayleighNumber.Gr over the interval 0 to 50 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name TSur (Sine), TFlu (Sine). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 9 s, rayleighNumber.Gr reads 514,750,528 and rayleighNumber.Ra reads 960,522,816. Across the run, the second channel ranges from -5.527e+09 to 5.38e+09. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 8.5 to 9 seconds. Subtracting 126,162,432 from 514,750,528 gives 388,588,096 source units. Its location brackets the change within one saved interval of 0.5 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

rayleighNumber.Gr (source units)

rayleighNumber.Ra (source units)

0

0

0

8.5

1.261624e+08

2.332533e+08

9

5.147505e+08

9.605228e+08

10

1.260517e+09

2.437747e+09

12.5

2.122277e+09

5.019744e+09

20

7.196529e+08

3.035414e+09

30

-1.704537e+09

-5.223971e+09

31

-1.767181e+09

-5.527017e+09

40

-1.233021e+07

-1.10273e+08

50

0

0

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.