The senExhTemOut.T trace covers 20 to 35.973 °C, a temperature span of 15.973 K. The first recorded maximum occurs at 187.2 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named HeatExchangerWithInputEffectiveness. The source file places it under Fluid, Heat Exchangers, Thermal Wheels, Latent. We used the 101 stored values for senExhTemOut.T over the interval 0 to 360 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name sin_2 (Boundary p T), sou_2 (Boundary p T), TSup (Ramp), sin_1 (Boundary p T). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel senExhRelHumIn.phi starts at 0.5, ends at 0.6927 and has a recorded range of 0.5 to 0.6927 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Heat exchanger with input effectiveness. The simulated senExhTemOut.T channel runs from 293.15 to 309.123 K over 360 seconds.
Heat exchanger with input effectiveness. The simulated senExhTemOut.T channel runs from 293.15 to 309.123 K over 360 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 3.6 seconds. Subtracting 293.15 from 299.941 gives 6.791 K. Its location brackets the change within one saved interval of 3.6 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

senExhTemOut.T (K)

senExhRelHumIn.phi (source units)

0

293.15

0.5

3.6

299.9411

0.6874478

72

300.1318

0.6927107

144

303.3435

0.6927112

187.2

309.1232

0.6927112

216

309.1117

0.6927112

288

309.1016

0.6927112

360

309.1016

0.6927112

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.