The recorded hex.Q1_flow channel spans 0 to 1,505 W in this reference run. It starts at 0 and ends at 1,178. The first recorded maximum occurs at 1,800 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named WetCoilCounterFlowPControl. The source file places it under Fluid, Heat Exchangers. We used the 101 stored values for hex.Q1_flow over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name con (Lim PID). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel hex.Q2_flow covers -1,558 to 0 W. At 36 s, the primary value is 1,477 and the companion is -1,558. Their signed difference is 3,035 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Heat exchanger with condensation and with feedback control. The simulated hex.Q1_flow channel runs from 0 to 1,505 W over 3,600 seconds.
Heat exchanger with condensation and with feedback control. The simulated hex.Q1_flow channel runs from 0 to 1,505 W over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed hex.Q1_flow samples by the trapezoidal rule gives 1.027 kWh over 3,600 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

hex.Q1_flow (W)

hex.Q2_flow (W)

0

0

0

36

1476.947

-1558.283

720

293.3756

-301.1678

1440

804.9448

-791.175

1800

1504.951

-1483.588

2160

1478.067

-1479.63

2880

1177.948

-1177.976

3600

1177.755

-1177.755

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.