The con.u_m trace ranges from 280.921 to 298.182 across 101 saved checkpoints. It begins at 293.15 and finishes at 298.15 after 3,600 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named WetCoilCounterFlowPIDControlAutoTuning. The source file places it under Fluid, Heat Exchangers. We used the 101 stored values for con.u_m over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 10 recorded variables. Alongside the primary output there are hex.m1_flow, hex.m2_flow, con.u_s, con.u_m, hex.Q1_flow. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

At 36 s, con.u_m reads 280.921 and con.u_s reads 288.15. Across the run, the second channel ranges from 283.15 to 298.15. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 36 seconds. Subtracting 293.15 from 280.921 gives -12.229 source units. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

con.u_m (source units)

con.u_s (source units)

0

293.15

288.15

36

280.9212

288.15

720

297.5742

298.15

1044

298.1818

298.15

1440

286.2436

286.15

2160

288.813

288.15

2880

288.15

288.15

3600

298.15

298.15

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.