The conS1.T[1] trace covers 11.784 to 20.881 °C, a temperature span of 9.097 K. The first recorded maximum occurs at 86,400 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ConductorInitialization. The source file places it under Heat Transfer. We used the 101 stored values for conS1.T[1] over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 9 recorded variables. Alongside the primary output there are conS1.T[2], conS1.T[3], conS1.T[1], conS1.Q_flow[5], conS1.Q_flow[4]. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel conS1.T[2] covers 288.501 to 295.792 K. At 0 s, the primary value is 284.934 and the companion is 288.501. Their signed difference is -3.567 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Heat conductor initialization. The simulated conS1.T[1] channel runs from 284.934 to 294.031 K over 86,400 seconds.
Heat conductor initialization. The simulated conS1.T[1] channel runs from 284.934 to 294.031 K over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 43,200 to 44,064 seconds. Subtracting 284.934 from 293.681 gives 8.748 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

conS1.T[1] (K)

conS1.T[2] (K)

0

284.9336

288.5007

17280

284.9336

288.5007

34560

284.9336

288.5007

43200

284.9336

288.5007

44064

293.6811

294.8435

51840

293.9818

295.646

69120

294.016

295.7482

86400

294.0306

295.7919

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.