The recorded heaCapGla.portUns.T temperature spans 20 °C to 20.27 °C in this simulation. That is a change of 0.27026 K. The first saved maximum occurs at 444 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named HeatCapacityVariableShadeDT. The source file places it under Heat Transfer, Windows. We used the 101 stored values for heaCapGla.portUns.T over the interval 0 to 600 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 4 recorded variables. Alongside the primary output there are heaCapGla.portUns.T, heaCapGla.portSha.T, heaCapGla.portUns.Q_flow, heaCapGla.portSha.Q_flow. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

At 6 s, heaCapGla.portUns.T reads 293.182 K and heaCapGla.portSha.Q_flow reads 22.02 W. Across the run, the second channel ranges from -0.00024903 W to 25 W. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Heat capacity with variable shade signal and different room temperature. The simulated heaCapGla.portUns.T channel runs from 293.15 to 293.42 K over 600 seconds.
Heat capacity with variable shade signal and different room temperature. The simulated heaCapGla.portUns.T channel runs from 293.15 to 293.42 K over 600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 6 seconds. Subtracting 293.15 from 293.182 gives 0.03223 K. Its location brackets the change within one saved interval of 6 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

heaCapGla.portUns.T (K)

heaCapGla.portSha.Q_flow (W)

0

293.15

25

6

293.1822

22.02012

120

293.3989

1.976289

240

293.4186

0.248307

360

293.4201

0.02908517

444

293.4203

0.007481888

480

293.4203

0.00352137

600

293.4203

-0.0002490286

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.