The lowest observed group mean is 858.407 for temperature (degrees F group 200. The highest is 1,211 for group -75, a difference of 352.16 on the source response scale. Across all 45 numeric records the response median is 991.5.
What was measured
The VANGEL32 data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as strength. It preserves the source scale and its sign. The file contains 3 numeric fields per accepted row.
Spread across the original readings
The two endpoint groups have 15 and 15 observations. Their medians are 846 and 1,197, respectively. The figure groups the original entries by the recorded temperature (degrees F value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

One row you can check
To check a real observation, take numeric row 7 after the header. Its response is 991.5. The overall arithmetic mean is 1,024, so this observation is -32.927 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 211.3, calculated by subtracting 872.9 from 1,084.
The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.
Worked data
temperature (degrees F group | Observations | Mean response | Median response | Minimum response | Maximum response |
|---|---|---|---|---|---|
-75 | 15 | 1210.567 | 1196.7 | 1009.7 | 1457.1 |
75 | 15 | 1004.307 | 991.5 | 863.6 | 1254.9 |
200 | 15 | 858.4067 | 846 | 806.5 | 949.8 |
Implications for an industrial comparison
Compare the specimen geometry, preparation, loading direction, conditioning and endpoint before using this distribution in a materials decision. Failure observations from a controlled test do not directly provide a field failure probability. A comparison with current production also needs the number of specimens withdrawn before the stated endpoint.
Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.
Source file and worked data
The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.
Cover photograph by Mikhail Nilov, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.