The TBrine_out.T trace covers 2.521 to 20 °C, a temperature span of 17.479 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named HeatPump_WaterWater. The source file places it under Fluid, Heat Pumps. We used the 101 stored values for TBrine_out.T over the interval 0 to 1,000 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 12 recorded variables. Alongside the primary output there are TBrine_out.T, TWater_out.T, heatPump.T_max, heatPump.T_min, TBrine_out_scaling.T. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel TWater_out.T covers 293.15 to 333.038 K. At 270 s, the primary value is 276.349 and the companion is 333.038. Their signed difference is -56.688 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

General and tester for a modulating water-to-water heat pump. The simulated TBrine_out.T channel runs from 275.671 to 293.15 K over 1,000 seconds.
General and tester for a modulating water-to-water heat pump. The simulated TBrine_out.T channel runs from 275.671 to 293.15 K over 1,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 10 seconds. Subtracting 293.15 from 286.265 gives -6.885 K. Its location brackets the change within one saved interval of 10 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

TBrine_out.T (K)

TWater_out.T (K)

0

293.15

293.15

10

286.2645

303.4557

200

281.2951

329.9726

400

281.0742

330.7349

600

280.5096

328.2591

800

278.0202

331.9802

870

275.671

329.4452

1000

281.2445

332.7449

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.