The archived response ranges from 30.7 to 34. The median is 32 and the central half of the measurements extends from 31.5 to 32.5. Those figures use all 160 numeric observations in this source series and retain its original measurement scale.

What was measured

The DDS1 data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as gate opening aperature. It preserves the source scale and its sign. The file contains 2 numeric fields per accepted row.

Spread across the original readings

The tenth percentile is 31.2 and the ninetieth is 33. They provide a narrower description of the typical spread than the minimum and maximum. The largest and smallest observed records are separated by 3.3. This is the range of this sample, rather than a guaranteed operating envelope.

Gate-opening aperture measurements. The 25th, 50th and 75th percentiles of the measurements are 31.5, 32 and 32.5.
Gate-opening aperture measurements. The 25th, 50th and 75th percentiles of the measurements are 31.5, 32 and 32.5. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 125 after the header. Its response is 32. The overall arithmetic mean is 32.021, so this observation is -0.02125 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 1, calculated by subtracting 31.5 from 32.5.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

Percentile

Observed response (source scale)

Number of numeric rows

0

30.7

160

10

31.2

160

25

31.5

160

50

32

160

75

32.5

160

90

33

160

100

34

160

Implications for an industrial comparison

A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.