The recorded gFun_int channel spans 0 to 3.23 source units in this reference run. It starts at 0 and ends at 3.23. The first recorded maximum occurs at 1,799,999,979,520 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named GFunction_SmallScaleValidation. The source file places it under Fluid, Geothermal, Borefields, Heat Transfer, Thermal Response Factors. We used the 101 stored values for gFun_int over the interval 0 to 1,799,999,979,520 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name gFun_int (Real), lntts_int (Real). The source declares nSeg = 12, nTimSho = 26, nTimLon = 50, nClu = 1. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 99.0% of its saved checkpoints at or above 1.615 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 3.208 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

G function small scale. The simulated gFun_int channel runs from 0 to 3.23 source units over 1,799,999,979,520 seconds.
G function small scale. The simulated gFun_int channel runs from 0 to 3.23 source units over 1,799,999,979,520 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 17,999,999,795 seconds. Subtracting 0 from 3.034 gives 3.034 source units. Its location brackets the change within one saved interval of 17,999,999,795 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

gFun_int (source units)

0

0

1.8e+10

3.033823

3.6e+11

3.226156

7.2e+11

3.228917

1.08e+12

3.229602

1.44e+12

3.229887

1.8e+12

3.230031

What to check on site

The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.