The gFun_int trace ranges from 0 to 3.4589 across 101 saved checkpoints. It begins at 0 and finishes at 3.4589 after 412,000,000 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named GFunction_1borehole_5meters. The source file places it under Fluid, Geothermal, Borefields, Heat Transfer, Thermal Response Factors. We used the 101 stored values for gFun_int over the interval 0 to 412,000,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name gFun_int (Real), lntts_int (Real). The source declares nBor = 1, hBor = 5, dBor = 1, rBor = 0.075. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 99.0% of its saved checkpoints at or above 1.729 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 3.432 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

G-function calculation for a field of 1 borehole. The simulated gFun_int channel runs from 0 to 3.459 source units over 412,000,000 seconds.
G-function calculation for a field of 1 borehole. The simulated gFun_int channel runs from 0 to 3.459 source units over 412,000,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 4,120,000 seconds. Subtracting 0 from 3.19 gives 3.19 source units. Its location brackets the change within one saved interval of 4,120,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

gFun_int (source units)

0

0

4120000

3.189567

8.24e+07

3.452597

1.648e+08

3.457016

2.472e+08

3.458151

3.296e+08

3.458628

4.12e+08

3.458882

What to check on site

The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.