The recorded dpBas channel spans -4 to 4 source units in this reference run. It starts at -4 and ends at 4. The first recorded maximum occurs at 1 seconds and the first minimum at 0 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named ExactInverses. The source file places it under Fluid, Flow Models. We used the 101 stored values for dpBas over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name dp (Pressure Difference), m_flow (Mass Flow Rate), m_flowBas (Mass Flow Rate), dpBas (Pressure Difference). The source declares k = 0.5, m_flow_turbulent = 0.3, tol = 1E-10. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel dpPow[2] covers -2.378 to 2.378 source units. At 0 s, the primary value is -4 and the companion is -2.378. Their signed difference is -1.622 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0.99 to 1 seconds. Subtracting 3.543 from 4 gives 0.4566 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | dpBas (source units) | dpPow[2] (source units) |
|---|---|---|
0 | -4 | -2.378414 |
0.2 | -0.2103075 | -0.3548783 |
0.4 | -0.00682765 | -0.01219321 |
0.6 | 0.006827644 | 0.0121932 |
0.8 | 0.2103075 | 0.3548783 |
0.99 | 3.543369 | 2.204882 |
1 | 4 | 2.378414 |
What to check on site
Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.
Cover photograph by Mikhail Nilov, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.