The recorded sha[1].fraSun channel spans 0 to 1 source units in this reference run. It starts at 0 and ends at 0. The first recorded maximum occurs at 57,888 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named FixedShade. The source file places it under Heat Transfer, Windows. We used the 101 stored values for sha[1].fraSun over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name HDirTil (Direct Tilted Surface), H (Replicator), incAng (Replicator). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel sha[2].fraSun covers 0.001 to 0.7573 source units. At 58,752 s, the primary value is 1 and the companion is 0.2753. Their signed difference is 0.7247 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Fixed shade. The simulated sha[1].fraSun channel runs from 0 to 1 source units over 86,400 seconds.
Fixed shade. The simulated sha[1].fraSun channel runs from 0 to 1 source units over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 58,752 to 59,616 seconds. Subtracting 1 from 0 gives -1 source units. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

sha[1].fraSun (source units)

sha[2].fraSun (source units)

0

0

0.001

17280

0

0.001

34560

0.8453017

0.5878124

51840

0.855617

0.5737974

57888

1.000303

0.3440188

58752

1

0.2752669

59616

0

0.001

69120

0

0.001

86400

0

0.001

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

Cover photograph by Jakub Zerdzicki, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.